Home Japanese Español Manufacturers Our Services Privacy Policy Our Location Contact Us
 
 
 
 
 
 
 
Now In: Lube USA >> Products >> Oil System (SLR) >> Automatic Intermittent Gear Pump AMR-II
 

Automatic Intermittent Gear Pump AMR-II
 
AMR-II
 
Specifications
Discharge volume 150cc/min (50Hz) , 180cc/min (60Hz)
Discharge pressure 0.8MPa (8kgf/cm²) 116psi
Power AC100V/1φ 200V/1φ (50/60Hz)
Rated current AC100V/0.83A, AC200V/0.41A (50Hz)
AC100V/0.64A, AC200V/0.33A (60Hz)
Motor 20W 2P Condenser motor
Working viscosity range 68?1300cSt
With Controller
Discharge time 2?90seconds
Interval 1?30minutes or 10?120minutes
Emergency detection Pressure, oil level
Emergency output contact type A contact
Emergency output contact capacity 0.5A/AC100V, 0.2A/AC200V
Without Controller
Emergency output contact type Oil level switch : A contact (ON at low level)
Pressure switch : A contact (Pressure up ON)
Emergency output contact capacity Oil level switch : 0.5A, AC?DC200V
Pressure switch : 2A, AC?DC250V,"
Reservoir capacity 1.8 ℓ , 3ℓ , : Resin, 4 ℓ , 8 ℓ : Metal
Weight 1.8 ℓ : 3.3kg/6.61lbs, 3 ℓ : 4kg/8.82lbs
 
Reservoir capacity 1.8ℓ
Part Number
With Controller
Without Controller
Motor Voltage
100V
200V
2~30 min timer
10~120 min timer
102301
102303
0
 
 
102302
102304
 
0
 
102317
102318
 
 
0

Reservoir capacity 3ℓ
Part Number
With Controller
Without Controller
Motor Voltage
100V
200V
2~30 min timer
10~120 min timer
102305
102307
0
 
 
102306
102308
 
0
 
102319
102320
 
 
0

Dimensional Drawing
Dimensional Drawing
 
Back To Top