Directions for use
- Use recommended greases.
- Never use molybdenum disulfide-contained grease.
- Use lithium greases. (Contact us for consultation when other than lithium grease is used.)
- Do not use any greases containing substances that attack brass and rubber.
- When refilling, take care not let foreign matter in the grease.
- Avoid continuous operation.
- After refilling, always press AIR BLEED push button to purge the pump of air.
- When refilling grease in main pipe and during test operation, stick to an intermittent cycle of running for 30 seconds and resting for 90 seconds. Failure to follow this requirement will result in thermal protector being activated by a heated solenoid, leaving the solenoid de-energized without pressure built up.
Specifications
| Pump |
Discharge volume |
10ml/min |
| Discharge pressure |
10MPa (safety valve set pressure) |
Power
DC24V AC100V , 200V , φ1 |
DC24V |
| Mortor |
20W/0.8A |
| Pressure relief solenoid |
26W/1.1A |
| Total |
46W/1.9A |
| Pressurization |
Max. ON time: 7.5 min. |
| Power distribution rate |
Max.25% (20°C) |
| Working consistency |
Cartridge grease No.000,00,0,1 |
| Recommended grease |
MP0, FS2, MT |
| Cartridge size |
200ml , 400ml , 700ml cartridge |
| Weight |
1.8kg (4C) , 2.8kg (7C) |
| Pressure relief |
Built-in solenoid |
|
Part Number
|
Model
|
Part Number
|
Model
|
|
103809
|
EGM-10S-4-2C
|
103811
|
EGM-10S-4-7C
|
|
103810
|
EGM-10S-4-4C
|
|
|
| Hydraulic Circuit Diagram |
 |
| Wiring Diagram |
 |
| Dimensional Drawing |

 |
|
| |
| Back To Top |
| |