Specifications
| Power consumption |
maximum 3W |
| Discharge time |
199sec |
| Interval time |
199min |
| Emergency output |
(x,x terminal)ON at low oil level and/or abnormal pressure
Contact capacity : AC250V, DC30V |
| Option |
(1) Oil level switch (Between o-o terminals)
(2) Pressure switch (Between P-Pterminals)
Use a switch with the minimum capacity of 12V, 10mmA
Do not connect to (NC) terminal (V)
Terminal (V) is used only when the controller is equipped with the condensor for motor. |
Lamp Indication
| POWER |
Green lamp is ON when power is turned ON |
| INT(INTERVAL) |
Yellow lamp is ON during interval |
| DIS(DISCHARGE) |
Green lamp is ON during discharge |
| EMG(EMERGENCY) |
Red lamp is ON at low oil level and / or abnormal pressure. |
| TIMER:Digital switch |
INTERVAL 099min
DISCHARGE 099sec |
| ALARM RESET |
Press the button to reset. |
INSTANT FEED
(Manual discharge) |
When pressed, it starts discharging and completes its discharge cycle set by the timer. |
| Part Number |
Model |
Power voltage |
Rated load |
Circit protector |
| 300041 |
ME2-T |
Single-phase AC100V/110V
50/60Hz±10% |
Single-phase 75W
motor or equal load |
2A |
| 300042 |
ME2-T |
Single-phase AC200V220V
50/60Hz±10% |
1A |
| 300043 |
ME2-T |
Three-phase AC200V/220V
50/60Hz±10% |
Three-phase 200W
motor or equal load |
| Operation Flow Chart |
 |
| Terminal Block Wiring Diagram |
 |
| Dimensional Drawing |
 |
|
| |
| Back To Top |
| |